Easy change nozzle introduced in 2008
Color-coded for easy size identification
Excellent durability
Warranted to maintain correct orifice size for five years
Wobbler technology produces low application intensity to preserve soil integrity.
Low pressure operation - 10 to 15 psi (0.69 to 1.03 bar) - saves money and energy.
Three different models available based on desired trajectory and droplet size.
UP3 snap-in nozzle is easy to remove for cleaning or changing. To remove the nozzle simply pinch and pull, then place and click to install.
The Xi-Wob must be mounted no more than 1 ft (0.3 m) below the truss rod on semirigid Polyethylene or steel drops. Do not use PVC drops.
The Xi-Wob can also be mounted on flexible hose drops when used with the Magnum Weight.
It is recommended that larger nozzle sizes be used only on soils that are suited for higher application rates.
For optimum performance, Senninger recommends the use of maximum spacing for 1-2 spans only.
Note : When outlet spacing exceeds 10 ft (3.0 m), keep Xi-Wobs above crop canopy. This is especially important on high profile crops. Not warranted for rigid installation on offsets or booms larger than 10.5 ft (3.2 m). Longer offsets and booms require a minimum of 2 ft (0.61 m) reinforced flex hose.
Wobbler technology provides outstanding uniformity over a large wetted area
More economical than other sprinkler packages
Low pressure operation – 10 psi (0.69 bar)–saves energy and provides larger droplet size
UP3 snap-in nozzle is easy to remove for cleaning.
The Xcel-Wobbler TOP must employ a 10 psi (0.69 bar) pressure regulator (PSR or PSR-2 recommended).
Use a 3/4' galvanized nipple or Senninger’s impact-modified thermoplastic nipple into the mainline (maximum 2 feet length). PVC nipples are not recommended.
The Xcel-Wobbler UP3 TOP is designed specifically for upright installation on top-of-pipe.
The Xcel-Wobbler UP3 TOP is not recommended for a manifold installation of two or more units from a single outlet.
Note : Any modifications or deletions regarding installation requirements will void warranty.
It is recommended that larger nozzle sizes be used only on soils that can handle higher application rates.
Color-coded band identifies each model based on flow (see chart below)
Durable design with an enclosed splasharm spring and bearing for protection from the elements
3/4' NPT brass connection for use in galvanized steel fittings
Hand Tight Nozzles eliminate the need for tools during renozzling; simply place and twist to install. Nozzles sizes are easily identified with color-coding. Warranted to maintain their correct orifice size for five years
It is recommended that larger nozzle sizes be used only on soils that can handle higher application rates. Larger flow models available. Square-orifice nozzles not recommended.
Prevent wind-drift losses
Minimize evaporative loss
Avoid wetting plant canopy in row crops
Achieve a more uniform root zone coverage
Can increase yield using less water
It is recommended that larger nozzle sizes be used only on soils that can handle higher application rates.
Can be used in conjunction with standard full circle LDNs or other Senninger sprinklers on the remainder of a pivot.
Distributes water in a 170° pattern with 17 streams at a 10° trajectory for minimum evaporative loss.
Integrated base allows the applicator to be installed directly into a pressure regulator or onto a standard 3/4' NPT female connection with no special threads or fittings required.
Maximum radius of throw- up to 29 ft (8.8 m)
UP3 snap-in nozzle is easy to remove for cleaning or changing. To remove the nozzle simply pinch and pull, then place and click to install.
Twenty-two versatile, easily changeable snap-in pads are available
No moving parts for longer product life
Can be mounted on top-of-pipe or on hose drops
UP3 snap-in nozzle is easy to remove for cleaning or changing. To remove the nozzle simply pinch and pull, then place and click to install.
It is recommended that larger nozzle sizes be used only on soils that can handle higher application rates.
Three models available: 180º single, 125º single, and 125º double
Lightweight for easier handling and installation
Lower freight costs
Available with either a 3/4' hose or 3/4' NPT male threaded outlet connection or the 180° single is also available with 19mm barb outlet connection.
Max recommended pressure: 120 psi (8.27 bar).
Max recommended flow: 20 gpm (4543 L/hr) or 15 gpm per side for the double model.
Max recommended water temperature: 110ºF (43º C).
Ambient temperatures to 150º F (66º C) will not damage goosenecks.
Attaches to mainline using galvanized nipple or Senninger’s impactmodified thermoplastic nipple (PVC nipples not recommended)
Wrench tighten using nipple hex until snug. Overtightening may cause issues.
If using a sealant, use only Teflon tape.
When using rigid drops in high profile crops, drop length should not exceed one foot below truss rod.
Easy to install
Color coded models for various truss rod sizes: 5/8' (rust), 11/ 16' (green), 3/4' (black), 13/ 16' (grey), 7/8' (blue)
Securely fastens 3/4' flexible hose to the truss rod to maintain the drop/sprinkler position and allows for easy adjustments
Supports flexible hose to prevent kinking and abrasive wear
Used in conjunction with the 125º model goosenecks
Helps reduce pattern interruption from colliding streams
Flows: 0.5 to 15 gpm (114 to 3407 L/hr) allows the use of the same model along the entire machine.
Each regulator maintains a constant preset outlet pressure based on its flow/inlet pressure.
Outlet pressures: 6 to 50 psi (0.41 to 3.45 bar)
Tamper-proof housing
Very low hysteresis and friction losses
100% pressure tested, to ensure quality and performance
Flows: 2.0 to 20 gpm (454 to 4542 L/hr) depending on model
Each regulator maintains a constant preset outlet pressure based on its flow/inlet pressure.
Outlet pressures: 6 to 60 psi (0.41 to 4.14 bar)
Very low hysteresis and friction losses
100% pressure tested, to ensure quality and performance
Flows: 0.5 to 8.0 gpm (114 to 1817 L/hr) depending on model
Each regulator maintains a constant preset outlet pressure based on its flow/inlet pressure.
Outlet pressures: 6 to 40 psi (0.41 to 2.76 bar)
Tamper-proof housing
Very low hysteresis and friction losses
100% pressure tested, to ensure quality and performance